Improved TR Isofas-LMG Improved λ TORUŃ Filmar Hotel POZNAŃ Novotel

ISOVENT-L

Product description:
For thermal, acoustic and fire insulation:

  1. external façades insulated by light-dry method,
  2. with stone, glass or PVC cladding etc.,
  3. attics, between rafters,
  4. floors between joists,
  5. ceilings cladded from bottom (suspended ceilings),
  6. in internal structures of partition walls,
  7. in cavity walls with ventilated and non-ventilated air gap,
  8. fillings of wooden or steel frame structures,
  9. in ventilated flat roofs.

 

Properties:
- light,
- elastic, easy adopting to insulated surface,
- easy in assembly and processing,
- non-flammable, excellent protection against fire,
- hydrophobized (do not absorb moisture),
- they tightly fit in insulated spaces, and therefore formation of thermal bridges is effectively avoided during assembly,
- they are produced of natural raw materials,
- ensure proper heat comfort and allow walls to breathe,
- resistant to chemical and biological corrosion,
- they are not subject to erosion, their durability exceeds that of plastics.

Insulation of external three-layer wall
1.Mineral plaster
2.Ceramic hollow-bricks
3.Ventilation gap
4.ISOVENT-L
5.Connector
6.Ceramic hollow bricks
7.Plaster

Parameters

MW Type ISOVENT-L
Product code (it describes the declared levels or classes of the product properties) MW-EN13162-T4-DS(TH)-CS(10)0,5-WS-MU1-WL(P)
Declared properties of the product in accordance to PN-EN 13162 Method of testing
Measure unit Levels or tolerances
Codes of classes or levels Values
Length (class of dimensional tolerance) PN-EN 822 [%] [-] ±2
Width (class of dimensional tolerance) [%] [-] ± 1,5
Thickness class<100 mm PN-EN 823 [mm/%] T4 - 3 mm / + 5 %
Thickness class≥100 mm [%/mm] - 3 % / + 5 mm
Dimensional stability under specified temperature and humidity conditions PN-EN 1604 [%] DS(TH) ± 1,0 (change in thickness, length and width)
Dimensional stability under specified temperature and humidity conditions [mm/m] ± 1 (change in flatness)
Short term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0
Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1
Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0
Declared thermal conductivity λD PN-EN 12667 [W/mK] [-]  0,036
Reaction to fire class PN-EN 13501-1 Od A do F Euroclass A1
Apparent density PN-EN 1602 [kg/m3] [-] 50

Declared thermal resistance RD for respective thicknesses of the product

Thickness [mm]
50 60 80 100 150 200
Thermal Resistance RD [m2 K/W]
1,35 1,65 2,20 2,75 4,15 5,55

Dimensions and packaging

Thickness of board Dimensions of board Number of boards in a packet Coverage area of a packet Volume of a packet Number of packets on a pallet Coverage area of boards on a pallet Volume of a boards on a pallet
LengthWidth
[mm]
[mm]
[mm]
[pcs.]
[m2]
[m3]
[pcs.]
[m2]
 [m3]
50 1000 500 12 6,00 0,300 20 120 6,000
610 12 7,32 0,366 16 117 5,856
60 1000 500 9 4,50 0,270 20 90 5,400
610 9 5,49 0,329 16 88 5,270
80 1000 500 6 3,00 0,240 20 60 4,800
610 6 3,66 0,293 16 59 4,685
100 1000 500 6 3,00 0,300 20 60 6,000
610 6 3,66 0,366 16 59 5,856
120 1000 500 5 2,50 0,300 20 50 6,000
610 5 3,05 0,366 16 48,8 5,856
150 1000 500 4 2,00 0,300 20 40 6,000
610 4 2,44 0,366 16 39 5,856
200 1000 500 3 1,50 0,300 20 30 6,000
610 3 1,83 0,366 16 29 5,856

Download │ ISOVENT-L