Improved TR Isofas-LMG Improved λ TORUŃ Filmar Hotel POZNAŃ Novotel

ISOVENT-M

Product description:
For thermal, acoustic and fire insulation of:

  1. external walls with panel façade (for instance made of sheet, board, siding),
  2. three-layer walls,
  3. external walls with stone or glass façade,
  4. stud walls,
  5. shell walls,
  6. partition walls,
  7. three-layer foundation walls,
  8. as an insulation in accoustic screens.

Properties:
- easy in assembly and processing,
- non-flammable, excellent protection against fire,
- hydrophobized (do not absorb moisture),
- they tightly fit in insulated spaces, and therefore formation of thermal bridges is effectively avoided during assembly,
- they are produced of natural raw materials,
- ensure proper thermal comfort and allow walls to breathe,
- resistant to chemical and biological corrosion,
- they are not subject to erosion, their durability exceeds that of plastics.

Insulation of external three-layer wall
1.Mineral plaster
2.Ceramic hollow-bricks
3.Ventilation gap
4.ISOVENT-M
5.Connector
6.Ceramic hollow bricks
7.Plaster

Parameters

MW Type ISOVENT-M
Product code (it describes the declared levels or classes of the product properties) MW-EN 13162-T3-DS(TH)-TR5-CS(10)10-WS-WL(P)-MU1-AW1
Declared properties of the product in accordance to PN-EN 13162 Method of testing
Measure unit Levels or tolerances
Codes of classes or levels Values
Length (class of dimensional tolerance) PN-EN 822 [%] [-] ± 2
Width (class of dimensional tolerance) [%] [-] ± 1,5
Thickness class<100 mm PN-EN 823 [mm/%] T3 - 3mm / + 10%
Thickness class≥100 mm [%/mm] - 3% / + 10mm
Dimensional stability under specified temperature and humidity conditions PN-EN 1604 [%] DS(TH) ± 1,0 (change in thickness, length and width)
Dimensional stability under specified temperature and humidity conditions [mm/m] ± 1 (change in flatness)
Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR 5 ≥ 5
Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)10 ≥ 10
Short term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0
Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0
Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1
Poziom ważonego współczynnika pochłaniania dźwięku   [-] AW1 1,00
Declared thermal conductivity λD PN-EN 12667 [W/mK] [-]  0,035
Reaction to fire class PN-EN 13501-1 A - F Euroclass A1
Apparent density PN-EN 1602 [kg/m3]

80 (for thickness < 80 mm)

75 (for thickness 80-100 mm)

65 (for thickness > 100 mm)

Declared thermal resistance RD for respective thicknesses of the product

Thickness [mm]
80 100 120 140 150 160 200
Thermal Resistance RD [m2 K/W]
2,25 2,85 3,40 4,00
4,25
4,57 5,70

Dimensions and packaging

Thickness of board Dimensions of board Number of boards in a packet Coverage area of a packet Volume of a packet Number of packets on a pallet Volume of a boards on a pallet
LengthWidth
80 1000 600 3 1,80 0,144 20 2,880
100 3 1,80 0,180 16 2,880
120 2 1,20 0,144 20 2,880
140 2 1,20 0,168 16 2,688
150 2 1,20 0,180 16 2,880
160 2 1,20 0,192 12 2,304
200 2 1,20 0,240 12 2,880

Download │ ISOVENT-M