Improved TR Isofas-LMG Improved λ TORUŃ Filmar Hotel POZNAŃ Novotel

ISOVENT-MW

Product description:
For thermal, acoustic and fire insulation of:
1. external walls with panel façade (for instance made of sheet, board, siding),
2. three-layer walls,
3. external walls with stone or glass façade, stud walls, shell walls,
4. partition walls,
5. three-layer foundation walls
6. as an acoustic insulation in acoustic screens

Special features:
Laminated boards are the cladding made of glass fibre tissue, which makes an excellent wind insulation.

Properties:
- easy in assembly and processing,
- non-flammable, excellent protection against fire,
- hydrophobized (do not absorb moisture),
- they tightly fit in insulated spaces, and therefore formation of thermal bridges is effectively avoided during assembly,
- they are produced of natural raw materials,
- ensure proper heat comfort and allow walls to breathe,
- resistant to chemical and biological corrosion,
- they are not subject to erosion, their durability exceeds that of plastics.

Insulation of external wall with glass cladding
1.Glass cladding
2.Ventilation gap
3.ISOVENT-MW
4.Concrete blocks
5.Plaster

Parameters

MW Type ISOVENT-MW
Product code (it describes the declared levels or classes of the product properties) MW-EN 13162-T3-DS(TH)-TR5-CS(10)0,5-10-WS-WL(P)-MU1-AW1
Declared properties of the product in accordance to PN-EN 13162 Method of testing
Measure unit Levels or tolerances
Codes of classes or levels Values
Length (class of dimensional tolerance) PN-EN 822 [%] [-] ± 2
Width (class of dimensional tolerance) [%] [-] ± 1,5
Thickness class<100 mm PN-EN 823 [mm/%] T3 - 3mm / + 10%
Thickness class≥100 mm [%/mm] - 3% / + 10mm
Dimensional stability under specified temperature and humidity conditions PN-EN 1604 [%] DS(TH) ± 1,0 (change in thickness, length and width)
Dimensional stability under specified temperature and humidity conditions [mm/m] ± 1 (change in flatness)
Tensile strength perpendicular to faces PN-EN 1607 [kPa] TR 5 ≥ 5
Compressive stress at 10% deformation PN-EN 826 [kPa] CS(10)10 ≥ 10
Short term water absorption PN-EN 1609 [kg/m2] WS ≤ 1,0
Long term water absorption by partial immersion PN-EN 12087 [kg/m2] WL(P) ≤ 3,0
Water vapour diffusion resistance factor PN-EN 12086 [-] MU1 ≤ 1
Poziom ważonego współczynnika pochłaniania dźwięku  EN ISO 11654
[-] AW1 1,00
Declared thermal conductivity λD PN-EN 12667 [W/mK] [-] ≤ 0,037
Reaction to fire class PN-EN 13501-1 A to F Euroclass A1

Declared thermal resistance RD for respective thicknesses of the product

Thickness [mm]
80 100 120 140 150 160 200
Thermal Resistance RD [m2 K/W]
2,15 2,70 3,20 3,75 4,05
4,30 5,40

Dimensions and packaging

Thickness of board Dimensions of board Number of boards in a packet
[pcs.]
Coverage area of a packet
[m2]
Volume of a packet
[m3]
Number of packets on a pallet
[pcs.]
Number of plates on a pallet
[pcs.]
Coverage area of boards on a pallet [m2]
Volume of a boards on a pallet [m3]
Length Width
80
1000
600
 3  
1,80 0,144 20
2,880
1200 1000   28 20,16 2,688
100 1000
 600  3 1,80
 0,180  16    2,880
1200  1000       22  15,84 2,640
120 
1000
 600  2  1,20  0,144  20    2,880
1200  1000       18  12,96 2,592
140 
1000
 600  2  1,20  0,168  16    2,688
1200  1000       16  11,52 2,688
150 
1000
 600  2  1,20  0,180  16    2,880
1200
 1000       16  11,52 2,880
160 
1000
 600  2  1,20  0,192  12+16    5,376
1200  1000       14  10,08 2,688
200 
1000
 600  2  1,20  0,240  12    2,880
1200
 1000       10  7,20 2,400